4. DESCRIPTION OF PARAMETERS
B–63610EN/01
116
NOTE
The time is counted in units of 8 ms. If the set value is not
a multiple of eight, it is raised to the next multiple of eight.
Example
When 30 is set, 32 ms is assumed.
3017 Output time of reset signal RST
[Data type] Byte
[Unit of data] 16 ms
[Valid data range] 0 to 255
To extend the output time of reset signal RST, the time to be added is
specified in this parameter.
RST signal output time = time veguired for reset + parameter 16 ms
3030 Allowable number of digits for the M code
3031 Allowable number of digits for the S code
3032 Allowable number of digits for the T code
3033 Allowable number of digits for the B code
[Data type] Byte
[Valid data range] 1 to 8
Set the allowable numbers of digits for the M, S, T, and B codes.
NOTE
Up to 5 digits can be specified in the S code