B–63610EN/01
4. DESCRIPTION OF PARAMETERS
137
MKP When M02, M30, or EOR(%) is executed during MDI operation, the
created MDI program is:
0 : Erased automatically.
1 : Not erased automatically.
NOTE
If the MER parameter (bit 6 of parameter No.3203) is 1,
executing the last block provides a choice of whether to
automatically erase a created program.
#7
MCK3205
#6 #5 #4
OSC
#3
PNS
#2
CMO
#1
CHG
#0
COL
[Data type] Bit
COL When a program is displayed or output, any colons (:) in the comments of
the program are:
0 : Converted to letter O
1 : Displayed or output as is
CHG When the change function of the extended edit function is used:
0 : Once the user has decided whether to make a change, the cursor is
moved to the target position.
1 : The cursor is moved to the change source, after which the user can
choose whether to make a change.
CMO In extended tape editing, the copy or move operation:
0 : Is performed in the usual way.
1 : Can also copy or move data from a program to a key–in buffer in units
of words.
PNS On the program screen, a search by a cursor key is:
0 : Performed.
1 : Not performed.
OSC On the offset screen, offset value erasure by a soft key is:
0 : Enabled.
1 : Disabled.
MCK The system tape memory check function is:
0 : Not used.
1 : Used. (This setting is inhibited.)
#7
3206
#6 #5 #4
PHS
#3 #2 #1
MIF
#0
[Data type] Bit
MIF Editing of the maintenance information screen is:
0 : Not prohibited.
1 : Prohibited.
PHS The selection of an operation history signal and parameters (No. 12801 to
No. 128900) are:
0 : Not linked.
1 : Linked.