B–63610EN/01
4. DESCRIPTION OF PARAMETERS
339
#7
8301
#6 #5
SYE
#4
SYA
#3 #2 #1 #0
SOF
[Data type] Bit
SYA In the servo–off state in simple synchronous control, the limit of the
difference between the positioning deviation of the master axis and that of
the slave axis is:
0 : Not checked.
1 : Checked.
SYE During execution of synchronization, the limit of the difference between
positioning deviations (parameter No. 8313 or 8323) is:
0 : Checked.
1 : Not checked.
SOF The synchronization funciton in simple synchronous control (one pair) is:
0 : Not used.
1 : Used.
#7
8302
#6 #5 #4 #3
SSE
#2 #1
ATS
#0
ATESMA
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
ATE Automatic setting of grid positioning for simplified synchronous control
one pair is:
0 : Disabled
1 : Enabled
ATS Automatic setting of grid positioning for simplified synchronous control
one pair is:
0 : Not started
1 : Started
NOTE
1 When the bits are set to 1, parameter No.8316 and bit 4
(APZx) of parameter No.1815 for the master and slave axes
are set to 0.
2 These bits are automatically set to 0 once grid positioning
has been completed.
SSE In simple synchronization control, the external machine coordinate
system shift function for the slave axis is:
0 : Not used.
1 : Used.
4.53
PARAMETERS OF
SIMPLE
SYNCHRONOUS
CONTROL