4. DESCRIPTION OF PARAMETERS
B–63610EN/01
198
Set the allowable error count for the error pulses between two spindles in
the serial spindle synchronization control mode or simple synchronous
control mode.
NOTE
This parameter is used to output the inter–spindle phase
error detection signal SYCAL in the serial spindle
synchronization control mode. The SYCAL <F044#4>
signal becomes “1” when a phase error exceeding the value
set in this parameter is found.
When you are going to use this parameter to detect error
pulses during simplified synchronization control, pay
attention to the mode of the spindle, and set the parameter
as required. (The parameter is invalid in spindle mode. It is
valid in Cs contour control, rigid tapping, and spindle
positioning mode; the detection unit per pulse differs,
however.)
4821 Master axis of first spindle under simple synchronous spindle control
4822 Master axis of second spindle under simple synchronous spindle control
NOTE
When this parameter has been set, the power must be
turned off before oparation is continued.
[Data type] Byte
[Valid data range] 1 to Number of spindles
Set the slave axis and master axis for simple synchronous spindle control
by spindles. Set the axis number of the master axis for the axis to be used
as the slave axis.
NOTE
1 This parameter is valid if bit 5 (SSY) of parameter No. 3704
is set to 1.
2 After this parameter is set, the power must be turned off then
back on for the setting to become effective.
4826
Permissible synchronization error under simple synchronous spindle control in
which the first spindle is the slave axis
4827
Permissible synchronization error under simple synchronous spindle control in
which the second spindle is the slave axis
[Data type] Word
[Unit of data] Pulse
[Valid data range] 0 to 32767