B–63610EN/01
4. DESCRIPTION OF PARAMETERS
275
High–speed skip function
Command
Input
signal
G31
HDI0 1S1
Multi–step skip function
Command
Input
signal
G31
G31P1
G04Q1
G31P2
G04Q2
G31P2
G04Q2
G31P4
G04Q4
G04
SKIP/HDI0 1S1 2S1 3S1 4S1 DS1
SKIP2 1S2 2S2 3S2 4S2 DS2
SKIP3 1S3 2S3 3S3 4S3 DS3
SKIP4 1S4 2S4 3S4 4S4 DS4
SKIP5 1S5 2S5 3S5 4S5 DS5
SKIP6 1S6 2S6 3S6 4S6 DS6
SKIP7 1S7 2S7 3S7 4S7 DS7
SKIP8 1S8 2S8 3S8 4S8 DS8
NOTE
HDI0 is high-speed skip signals.
#7
6210
#6 #5 #4 #3 #2 #1
ROS
#0
[Data type] Bit
ROS When the skip position goes beyond the roll–over range, the values of
system variables #5061 through #5068 indicating the skip signal position:
0 : Are not rolled over.
1 : Are rolled over similar to the absolute coordinates.
#7
6215
#6 #5 #4 #3 #2 #1 #0
CST
[Data type] Bit axis
CST For the Cs contour controlled axis, the torque limit skip function is:
0 : Disabled.
1 : Enabled.
Torque limit skip operation is performed for the Cs counter controlled
axis by using the serial spindle torque limit command signal
TLMH<G070, G074, G204, G266> and the load detection signal
LDT1<F045, F049, F196, F266>.