4. DESCRIPTION OF PARAMETERS
B–63610EN/01
126
#7
3115
#6
D10x
#5 #4 #3
NDFx
NDFx
#2
SFMx
#1
NDAx
NDAx
#0
NDPx
NDPx
[Data type] Bit axis
NDPx Display of the current position for each axis
0 : The current position is displayed.
1 : The current position is not displayed.
NDAx Position display using absolute coordinates and relative coordinates is:
0 : Performed.
1 : Not performed. (Machine coordinates are displayed.)
SFMx In current position display, subscripts are:
0 : Added to the absolute, relative, and machine coordinate axis names.
1 : Assed only to the machine coordinate axis names.
NDFx To the actual speed display, axis movement data is:
0 : Added.
1 : Not added.
NOTE
Even if the PCF parameter (bit 1 of parameter No.3105) is
set to 0, so as to add PMC controlled axis movement data
to the actual speed display, the movement data for a PMC
controlled axis for which NDFx is set to 1 is not added to the
actual speed display.
D10x The current positions (absolute position, relative position, machine
position, remaining travel, and travel by manual handle interrupt), and
workpiece zero–point offset are:
0 : Displayed as usual. (Not multiplied by ten.)
1 : Multiplied by ten, and displayed.
Example: The current position on the Y–axis is multiplied by ten and
displayed.
X 1.2345 → X 1.2345
Y 1.2345 → Y 12.345
Z 1.2345 → Z 1.2345
#7
MDC3116
#6
T8D
#5
COA
#4
FOV
#3 #2
PWR
#1 #0
MDP
[Data type] Bit
MDP The memory card input/output screen is:
0 : Not displayed.
1 : Displayed.
PWR Alarm No.100 (parameter enable) :
0 : Clear by
CAN
+
RESET
key
1 : Clear by
RESET
key
FOV In the field of specified feedrate F on the program check screen,
0 : The specified feedrate is displayed.
1 : (Specified feedrate) x (override) is displayed.