B–63610EN/01
4. DESCRIPTION OF PARAMETERS
25
0203 Baud rate (for remote diagnosis)
[Data type] Byte
Set the baud rate of data input/output by remote diagnosis, with reference
to the tables given below.
When using an RS–232C serial port
Setting Baud rate (bps)
7
8
9
10
600
1200
2400
4800
9600
19200
Setting Baud rate (bps)
1
2
3
4
5
50
100
110
150
200
300
6
11
12
When using a modem card (when bit 6 (MCB) of parameter No. 201 is
set to 1)
Setting Baud rate (bps)
7
8
9
10
600
1200
2400
4800
9600
19200
Setting Baud rate (bps)
1
2
3
4
5
28800
38400
57600
300
6
11
12
–
–
NOTE
The tables above indicate the baud rates of communication
between the CNC and modem. The actual communication
baud rate may be lowered, depending on the modem and
communication line.
0204 Remote diagnosis channel
[Data type] Byte
[Valid data range] 0, 1, 2
The interface to be used for remote diagnosis is:
0, 1: RS–232C serial port 1 (channel 1).
2: RS–232C serial port 2 (channel 2).
To carry out remote diagnosis using RS–232C, the reader/punch interface
is required.