B–63610EN/01
4. DESCRIPTION OF PARAMETERS
31
#7
0801
#6 #5 #4 #3 #2 #1 #0
SB2
[Data type] Bit
SB2 The number of stop bits is:
0 : 1 bit.
1 : 2 bits.
0802 Communication channel for the FACTOLINK
[Data type] Byte
0803 Communication baud rate for the FACTOLINK
[Data type] Byte
#7
0810
#6 #5
FMN
#4
FTM
#3
FYR
#2
FCL
#1
FAS
#0
BGS
[Data type] Bit
BGS When the FACTOLINK screen is not displayed, FACTOLINK alarm task
communication is:
0 : Not activated.
1 : Activated.
FAS If FACTOLINK uses the Answer or AnswerEx command, the answer
number A01. is:
0: Displayed in the answer field.
1: Not displayed in the answer field.
FCL The FACTOLINK clock is:
0: Not displayed in reverse video.
1: Displayed in reverse video.
FYR In the FACTOLINK clock display, years in the 99/01/23 00:00 format (bit
4 (FTM) of parameter No. 810 set to 1) are represented:
0: By a two–digit number.
1: By a four–digit number.
FTM The FACTOLINK clock is displayed in this format:
0: Wed Nov 12 00:00:00
1: 97/11/12 00:00:00
FMN The FACTOLINK screen is displayed:
0: In color.
1: With two levels of gray.
0811 Logging type for the FACTOLINK
[Data type] Byte
0812 PMC address of logging data for the FACTOLINK
[Data type] Word
4.7
PARAMETERS OF
FACTOLINK