B–63610EN/01
4. DESCRIPTION OF PARAMETERS
351
#7
8700
#6 #5 #4 #3
DMM
#2 #1 #0
[Data type] Bit
DMM In DNC operation from the PMC, OPEN CNC, or C–EXE, pre–reading
is:
0 : Not performed.
1 : Performed.
#7
8701
#6 #5 #4 #3 #2
WPR
#1
PLD
#0
[Data type] Bit
PLD When the P–code loader function is used (macro compiler/executor):
0 : AM is initialized and the entire contents of RAM are rewritten.
1 : RAM is not initialized, being overwritten instead
WPR The function that allows parameters that are rewritten using the PMC
window to be enabled during automatic operation is:
0 : Disabled.
1 : Enabled.
NOTE
If this parameter is set, a move command based on manual
operation is disabled (interlock state) while parameter
rewriting using the PMC window is being executed.
#7
LFM8702
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
LFM At the beginning of program uploading in response to a request using the
data window library:
0 : “LF+%” is not output.
1 : “LF+%” is output.