B–63610EN/01
4. DESCRIPTION OF PARAMETERS
287
6483
M code (1) in group S for backward movement by the manual handle retrace
function
6484
M code (2) in group S for backward movement by the manual handle retrace
function
6485
M code (3) in group S for backward movement by the manual handle retrace
function
6486
M code (4) in group S for backward movement by the manual handle retrace
function
6487
M code (1) in group T for backward movement by the manual handle retrace
function
6488
M code (2) in group T for backward movement by the manual handle retrace
function
6489
M code (3) in group T for backward movement by the manual handle retrace
function
6490
M code (4) in group T for backward movement by the manual handle retrace
function
[Data type] Word
[Unit of data] 0 to 9999
These parameters set the M codes in each group for backward movement
by the manual handle retrace function.
For backward movement for an M code, the modal M code in the same
group set by the parameter is output. The first M code in each group is set
as the default at a reset.
When the number of M codes in a group is 3 or less, set the parameter
corresponding to an unused M code to 0.
(For backward movement for “M0”, “M0” is output regardless of which
M code is set for the parameter.)
For an M code which is not set in any group by any of the above
parameters, the M code for forward movement is output.