B–63610EN/01
4. DESCRIPTION OF PARAMETERS
141
3270 Number of the LCD unit of which MDI is selected at power–up
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Byte
[Valid data range] 0, 1
If the function to connect two LCD units is used, set the LCD unit of
which MDI is selected at power–up. This parameter is valid if bit 0 (LCH)
of parameter No. 3260 is set to 0.
[Sample settings]
D If just a single LCD is connected, set 0.
D If two LCD units are connected and if MDI of the second unit is
selected, set 1.
NOTE
If the setting is greater than the number of actually
connected units, MDI of the last LCD unit is selected.
3271 Number of the LCD unit of which MDI is being selected
[Data type] Byte
[Valid data range] 0, 1
The number of the LCD unit of which MDI is enabled is automatically set.
[Sample display]
D If just a single LCD unit is connected, 0 is displayed.
D If two LCD units are selected and if MDI of the second unit is selected,
1 is displayed.
NOTE
The setting cannot be changed from MDI or the like.
#7
KEY3290
#6
MCM
#5 #4
IWZ
#3
WZO
#2
MCV
#1
GOF
#0
WOF
[Data type] Bit
WOF Setting the tool offset value by MDI key input is:
0 : Not disabled
1 : Disabled (With parameter No.3294 and No.3295, set the offset
number range in which updating the setting is to be disabled.)
GOF Setting the tool offset value by MDI key input is:
0 : Not disabled
1 : Disabled (With parameter No.3294 and No.3295, set the offset
number range in which updating the setting is to be disabled.)
MCV Macro variable setting by MDI key input is:
0 : Not disabled
1 : Disabled