4. DESCRIPTION OF PARAMETERS
B–63610EN/01
134
NOTE
This improvement is valid if the hardware is equipped with
a separate buzzer.
TB2 If a buzzer is provided and if bit 3 (TBZ) of parameter No. 3192 is set to 1,
0 : Pressing any point on the touch panel causes the buzzer to sound. If
any point is kept pressed, the buzzer continues sounding.
1 : The buzzer sounds when the pressing on the touch panel is recognized
as a key.
3197 Detection time of continuous pressing on touch panel
[Data type] Byte
[Unit of data] s
[Valid data range] 0 to 255
This parameter is valid if bit 2 (TRA) of parameter No. 3192 is set to 1.
Set a period of continuous pressing on the touch panel which causes
P/S5305 alarm to be raised. If 0 is set, a period of 20 s is assumed.
#7
MIP3201
#6
NPE
#5
N99
#4 #3
PUO
#2
REP
#1
RAL
#0
RDL
[Data type] Bit
RDL When a program is registered by input/output device external control
0 : The new program is registered following the programs already
registered.
1 : All registered programs are deleted, then the new program is
registered.
Note that programs which are protected from being edited are not
deleted.
RAL When programs are registered through the reader/puncher interface
0 : All programs are registered.
1 : Only one program is registered.
REP Action in response to an attempt to register a program whose number is
the same as that of an existing program
0 : An alarm is generated.
1 : The existing program is deleted, then the new program is registered.
Note that if the existing program is protected from being edited, it is
not deleted, and an alarm is generated.
PUO When address O of a program number is output in ISO code:
0 : “:” is output.
1 : “O” is output.
N99 With an M99 block, when bit 6 (NPE) of parameter No.3201 = 0, program
registration is assumed to be:
0 : Completed
1 : Not completed
NPE With an M02, M30, or M99 block, program registration is assumed to be:
0 : Completed
1 : Not completed