B–63610EN/01
4. DESCRIPTION OF PARAMETERS
303
#7
6901
#6 #5 #4 #3
PSF
#2
PCM
PCM
#1
EPS
EPS
#0
IGP
IGP
[Data type] Bit
IGP During follow–up for the absolute position detector, position switch
signals are:
0 : Output
1 : Not output
EPS The number of position switches is:
0 : Up to 10.
1 : Up to 16.
PCM Position switch signals are output:
0 : Without considering acceleration/deceleration and servo delay.
1 : With considering acceleration/deceleration and servo delay.
PSF In AI–look–ahead control mode or look–ahead control mode, position
switches are:
0 : Not used.
1 : Used.
NOTE
The position switch signals are output considering
acceleration/deceleration after interpolation and servo
delay. Acceleration/deceleration after interpolation and
servo delay are considered even for position switch signal
output in a mode other than the AI look–ahead control and
look–ahead control modes. When this parameter is set to 1,
however, signals are output from the position switches at
different times from the specified ones.
4.41
PARAMETERS OF
POSITION SWITCH
FUNCTIONS