4. DESCRIPTION OF PARAMETERS
B–63610EN/01
128
1 : The value calculated from the spindle motor speed (the same as the
spindle speed displayed on the operating monitor screen).
#7
NVG
3119
#6 #5 #4
F2K
#3
TPA
TPA
#2
DDS
DDS
#1
POR
POR
#0
NVG
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
POR Display in Portuguese is:
0 : Disabled.
1 : Enabled.
DDS When the touch panel option is available, the touch panel is:
0: Enabled.
1: Disabled.
TAP When the external touch panel option is available, the external touch
panel is:
0: Enabled.
1: Disabled.
F2K As the LCD/MDI keyboard, Symbol CAPi T (CAP–II) combined with a
unified standard keyboard is:
0 : Not used.
1 : Used.
NVG When a color display device is used, VGA mode is:
0 : Used.
1 : Not used.
3120
Time from the output of an alarm to the termination of sampling (waveform diag-
nosis function)
[Data type] Word
[Unit of data] ms
[Valid data range] 1 to 32760
When the waveform diagnosis function is used, this parameter sets the
time form the output of a servo alarm until data collection. Storage
operation is stopped because of the alarm. (This means that the
termination of data collection can be delayed by a specified time.)
3122 Time interval used to record time data in operation history
[Data type] Word
[Unit of data] min
[Valid data range] 0 to 1439
Time data is recorded in operation history at set intervals. When 0 is
specified in this parameter, 10 minutes is assumed as the default.
However, note that time data is not recorded if there is no data to be
recorded at the specified time.