B–63610EN/01
4. DESCRIPTION OF PARAMETERS
135
MIP Program registration by external start signal (MINP) :
0 : Not performed.
1 : Performed.
#7
3202
#6
PSR
#5
CPD
#4
NE9
#3
OSR
#2
CND
#1
OLV
#0
NE8
[Data type] Bit
NE8 Editing of subprograms with program numbers 8000 to 8999
0 : Not inhibited
1 : Inhibited
The following edit operations are disabled:
(1) Program deletion (Even when deletion of all programs is specified,
programs with program numbers 8000 to 8999 are not deleted.)
(2) Program output (Even when outputting all programs is specified,
programs with program numbers 8000 to 8999 are not output.)
(3) Program number search
(4) Program editing of registered programs
(5) Program registration
(6) Program collation
(7) Displaying programs
OLV When a program other than the selected program is deleted or output:
0 : The display of the selected program is not held.
1 : The display of the selected program is held.
CND By using the [CONDENSE] soft key on the program directory screen, the
program condensing operation is:
0 : Not performed. (The [CONDENSE] soft key is not displayed.)
1 : Performed.
OSR In programming number search, when pressing soft key [O–SEARCH]
without inputting program number by key :
0 : Search the following program number
1 : Operation is invalid
NE9 Editing of subprograms with program numbers 9000 to 9999
0 : Not inhibited
1 : Inhibited
The following program editing during operation is invalid.
(1) Program deletion (Even when deletion of all programs is specified,
programs with program numbers 9000 to 9999 are not deleted.)
(2) Program punching (Even when punching of all programs is specified,
programs with program numbers 9000 to 9999 are not punched.)
(3) Program number search
(4) Program editing after registration
(5) Program registration
(6) Program collation
(7) Displaying programs