4. DESCRIPTION OF PARAMETERS
B–63610EN/01
46
#7
WZR
1201
#6 #5
AWK
AWK
#4 #3
FPC
FPC
#2
ZCL
ZCL
#1
ZPI
ZPI
#0
ZPR
ZPR
[Data type] Bit
ZPR Automatic setting of a coordinate system when the manual reference
position return is performed
0 : Not set automatically
1 : Set automatically
NOTE
1 ZPR is valid while a workpiece coordinate system function
is not provided. If a workpiece coordinate system function
is provided, making a manual reference position return
always causes the workpiece coordinate system to be
established on the basis of the workpiece origin offset
(parameters No. 1220 to No. 1226), irrespective of this
parameter setting.
2 If an absolute–position coder is used in a system not using
a workpiece coordinate system function, set this parameter.
ZPI Coordinates at the reference position when a coordinate system is set
automatically
0 : Value set in parameter No.1250 is used.
1 : For input in mm, the value set in parameter 1250 is used, or for input in
inches, the value set in parameter No.1251 is used.
This bit is ineffective, when a workpiece coordinate system option is
provided, however.
ZCL Local coordinate system when the manual reference position return is
performed
0 : The local coordinate system is not canceled.
1 : The local coordinate system is canceled.
FPC When the floating reference position is specified using soft keys on the
current position display screen
0 : The value of the displayed relative position is not preset. (In other
words, the value does not change.)
1 : The value of the displayed relative position is preset to 0.
AWK When the workpiece zero point offset value is changed
0 : The absolute position display changed when the next bufforing block
is performed.
1 : The absolute position display is changed immediately.
Changed value is valid ofter baffering the next block.
WZR Upon reset, the workpiece coordinate system is:
0 : Not returned to that specified with G54
1 : Returned to that specified with G54
4.12
PARAMETERS OF
COORDINATES