4. DESCRIPTION OF PARAMETERS
B–63610EN/01
356
#7
12001
#6 #5 #4 #3 #2 #1 #0
IMR
[Data type] Bit
IMR If an attempt is made to enter a program having the same program number
as a built–in macro program that has already been entered,
0: An alarm is raised.
1: The built–in program is deleted, then the new program is entered.
However, if the built–in program is edit–prohibited, the program is
not deleted, but an alarm is raised.
REP
(Prm.No.3201#2)
IMREP
(Prm.No.12001#0)
Program stored
on tape
Built–in macro
program
0
0 Alarm Alarm
0
1 Alarm Overwrite
1
0 Overwrite Alarm
1
1 Overwrite Overwrite
NOTE
1 This parameter is rewritten by the built–in macro data in
FROM at power–up or at a reload operation.
2 If the key of parameter No. 12013 is locked, the built–in
macro data in FROM is used.
12010 Built–in macro program referencing or editing enabled/disabled
[Data type] Byte
[Valid data range] 0 to 2
This parameter specifies whether referencing or editing of a built–in
macro program is enabled or disabled.
Prm.No.12010 Edit Reference
0
1
Ę
2
Ę Ę
NOTE
1 This parameter is rewritten by the built–in macro data in
FROM at power–up or at a reload operation.
2 If the key of parameter No. 12013 is locked, the built–in
macro data in FROM is used.
4.57
PARAMETERS OF
BUILT–IN MACRO