B–63610EN/01
4. DESCRIPTION OF PARAMETERS
307
#7
7001
#6 #5 #4 #3 #2 #1 #0
MIN
[Data type] Bit
MIN The manual intervention and return function is:
0 : Disabled.
1 : Enabled.
7015 Least command increment setting for jog feed
[Data type] Word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 10000
This parameter sets the least command increment for jog feed when PMC
signal JGUNIT <bit 0 of G0023> is set to 1. If the setting of this parameter
is 0, a value of 1 is recognized.
#7
7054
#6 #5
AIL
#4 #3
AZR
#2 #1
AIR
#0
[Data type] Bit
AIR In AI look–ahead control mode, the rapid traverse type is:
0 : Linear interpolation type.
1 : According to the setting of bit 1 (LRP) of parameter No. 1401.
AZR In AI look–ahead control mode, the G27, G28, G30, G30.1, and G53
commands are executed:
0 : In normal mode. (Look–ahead feed forward is valid.)
1 : In AI contour control mode.
AIL When non–linear type positioning is specified in AI look–ahead control
mode and an axis–by–axis interlock signal is input:
0 : The tool stops along all axes.
1 : The setting of bit 4 (XIF) of parameter No. 1002 is used.
4.42
PARAMETERS OF
MANUAL OPERATION