4. DESCRIPTION OF PARAMETERS
B–63610EN/01
318
7284 Name of general–purpose switch on software operator’s panel (extended)
7285 Name of general–purpose switch on software operator’s panel (extended)
7286 Name of general–purpose switch on software operator’s panel (extended)
::
7299 Name of general–purpose switch on software operator’s panel (extended)
7352 Name of general–purpose switch on software operator’s panel (extended)
7353 Name of general–purpose switch on software operator’s panel (extended)
7354 Name of general–purpose switch on software operator’s panel (extended)
::
7399 Name of general–purpose switch on software operator’s panel (extended)
[Data type] Byte
OPERATOR’S PANEL O1234 N5678
SIGNAL1 : OFF ON
SIGNAL2 : OFF ON
SIGNAL3 : OFF ON
SIGNAL4 : OFF ON
SIGNAL5 : OFF ON
SIGNAL6 : OFF ON
SIGNAL7 : OFF ON
SIGNAL8 : OFF ON
These names are set using the character codes displayed in parameters
No.7284 through No.7299, and parameters No.7352 through No.7399.
Parameter No.7284:
Set the character code (083) corresponding to S of SIGNAL 9.
Parameter No.7285:
Set the character code (073) corresponding to I of SIGNAL 9.
Parameter No.7286:
Set the character code (071) corresponding to G of SIGNAL 9.
Parameter No.7287:
Set the character code (078) corresponding to N of SIGNAL 9.
Parameter No.7288:
Set the character code (065) corresponding to A of SIGNAL 9.
Parameter No.7289:
Set the character code (076) corresponding to L of SIGNAL 9.
Parameter No.7290:
Set the character code (032) corresponding to (space) of SIGNAL 9.
Parameter No.7291:
Set the character code (057) corresponding to 9 of SIGNAL 9.
Similarly, set character codes as shown below.
Parameter No.7292 to No.7299: Set character codes for SIGNAL 10, shown above.
Parameter No.7352 to No.7359: Set character codes for SIGNAL 11, shown above.
Parameter No.7360 to No.7367: Set character codes for SIGNAL 12, shown above.
Parameter No.7368 to No.7375: Set character codes for SIGNAL 13, shown above.
Parameter No.7376 to No.7383: Set character codes for SIGNAL 14, shown above.
Parameter No.7384 to No.7391: Set character codes for SIGNAL 15, shown above.
Parameter No.7392 to No.7399: Set character codes for SIGNAL 16, shown above.
The character codes are shown in the character code correspondence table
in Appendix A.
Set the names of the
general–purpose switches
(SIGNAL 9 to SIGNAL
16) on the software
operator’s panel, as
described below.