B–63610EN/01
4. DESCRIPTION OF PARAMETERS
15
0024 Port for communication with the PMC ladder development tool (FAPT LADDER–II/III)
[Data type] Byte
This parameter sets the port to be used for communication with the PMC
ladder development tool (FAPT LADDER–II/III).
0 : HSSB (COP7)
1 : RS–232C serial port 1 (JD36A)
2 : RS–232C serial port 2 (JD36B)
3 : Remote buffer interface (RS–232C) (JD28A)
#7
ENS0100
#6
IOP
#5
ND3
#4 #3
NCR
#2
CRF
#1
CTV
#0
[Data type] Bit
CTV: Character counting for TV check in the comment section of a program.
0 : Performed
1 : Not performed
CRF EOB (end of block) to be output in the ISO code:
0: Depends on the setting of bit 3 (NCR) of parameter No. 100.
1: is “CR”“LF”.
Note) The EOB output patterns are as shown below:
NCR CRF EOB output format
0 0 “LF” “CR” “CR”
0 1 “CR” “LF”
1 0 “LF”
1 1 “CR” “LF”
NCR Output of the end of block (EOB) in ISO code
0 : LF, CR, CR are output.
1 : Only LF is output.
ND3 In DNC operation, a program is:
0 : Read block by block. (A DC3 code is output for each block.)
1 : Read continuously until the buffer becomes full. (A DC3 code is
output when the buffer becomes full.)
NOTE
In general, reading is performed more efficiently when ND3
set to 1. This specification reduces the number of buffering
interruptions caused by reading of a series of blocks
specifying short movements. This in turn reduces the
effective cycle time.
IOP Specifies how to stop program input/output operations.
0 : An NC reset can stop program input/output operations.
1 : Only the [STOP] soft key can stop program input/output operations.
(An reset cannot stop program input/output operations.)
4.2.1
Parameters Common
to all Channels