B–63610EN/01
4. DESCRIPTION OF PARAMETERS
353
8760
Program number for data registration (data input/output function using the
I/O link)
[Data type] Word
[Valid data range] 0 to 9999
When the data input/output function using the I/O link is used, this
parameter sets the program numbers of the programs to be used for
registering data (parameters, macro variables, and diagnostic data) from
Power Mates.
For a Power Mate in group n, the following program numbers are used:
For parameters: Setting + n 10 + 0
For macro variables: Setting + n 10 + 1
For diagnostic data: Setting + n 10 + 2
Example: When 8000 is set
8000: Parameters of group 0 (I/O channel = 20)
8001: Macro variables of group 0 (I/O channel = 20)
8002: Diagnostic data of group 0 (I/O channel = 20)
8010: Parameters of group 1 (I/O channel = 21)
8011: Macro variables of group 1 (I/O channel = 21)
8012: Diagnostic data of group 1 (I/O channel = 21)
8020: Parameters of group 2 (I/O channel = 22)
8021: Macro variables of group 2 (I/O channel = 22)
8022: Diagnostic data of group 2 (I/O channel = 22)
8150: Parameters of group 15 (I/O channel = 35)
8151: Macro variables of group 15 (I/O channel = 35)
8152: Diagnostic data of group 15 (I/O channel = 35)
NOTE
When 0 is set, the input/output of parameters, macro
variables, and diagnostic data cannot be performed, but
program input/output processing is performed.
8781 Amount of DRAM used with the C executor
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] 64k Byte
[Valid data range] 16 to 64
This parameter sets the amount of DRAM to be used by the C executor.
Specify a size of no less than 1024K bytes, in multiples of 64K bytes. If
a value that exceeds the valid data range is specified, 0 is assumed.