4. DESCRIPTION OF PARAMETERS
B–63610EN/01
160
3627
Pitch error compensation (absolute value) at reference position when a move-
ment to the reference position is made from the direction opposite to the direc-
tion of reference position return
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] –32768 to 32767
Set the absolute value of pitch error compensation at reference position
when a movement to the reference position is made from the negative
direction if the direction of reference position return (bit 5 (ZMI) of
parameter No. 1006) is positive or from the positive direction if the
direction of reference position return is negative.
3661
Number of pitch error compensation point in the reference position if pitch error
compensation is carried out on an axis of Cs contour control on the slave side
during simple synchronous spindle control (for the first spindle)
3662
Number of pitch error compensation point in the reference position if pitch error
compensation is carried out on an axis of Cs contour control on the slave side
during simple synchronous spindle control (for the second spindle)
3666
Number of pitch error compensation point at the farthest end in the negative
direction if pitch error compensation is carried out on an axis of Cs contour con-
trol on the slave side during simple synchronous spindle control (for the first
spindle)
3667
Number of pitch error compensation point at the farthest end in the negative
direction if pitch error compensation is carried out on an axis of Cs contour con-
trol on the slave side during simple synchronous spindle control (for the second
spindle)