B–63610EN/01
4. DESCRIPTION OF PARAMETERS
165
#7
3702
#6 #5 #4 #3
OR2
#2
OR1
#1 #0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
OR1 Whether the stop–position external–setting type orientation function is
used by the first spindle motor
0 : Not used
1 : Used
OR2 Whether the stop–position external–setting type orientation function is
used by the second spindle motor
0 : Not used
1 : Used
#7
3703
#6 #5 #4 #3
MPP
#2 #1 #0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
MPP Under multi–spindle control, the spindle is not selected by a spindle
signal (SWS1 to SWS2 <G027 bits 0 to 1, G026 bit 3>), and a
programmed command (address P) is:
0 : Not used.
1 : Used.
NOTE
If this parameter is set to 1, set parameters No. 3781 to No.
3782 as well.
#7
CSS3704
#6 #5
SSY
#4
SSS
#3 #2 #1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
SSS Synchronous spindle control by each spindle is:
0 : Not performed.
1 : Performed.
The master axis and slave axis of synchronous spindle control can be
selected from the first to second spindles.