B–63610EN/01
4. DESCRIPTION OF PARAMETERS
277
#7
6240
#6 #5 #4 #3 #2 #1 #0
AE0
[Data type] Bit
AE0 Measurement position arrival is assumed when the automatic tool
compensation signals XAE and ZAE (bits 0 and 1 of X004) (T system) or
the automatic tool length measurement signals XAE, YAE, and ZAE (bits
0, 1, and 2 of X004) (M system) are:
0 : 1
1 : 0
6241
Feedrate during measurement of automatic tool compensation
Feedrate during measurement of automatic tool length compensation
[Data type] Word
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
This parameter sets the feedrate during measurement of automatic tool
compensation (T series) and automatic tool length compensation (M series).
6251
g value on X axis during automatic tool compensation
g value during automatic tool length automatic compensation
6252
g value on Z axis during automatic tool compensation
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
[Valid data range] 1 to 99999999
These parameters set the e value during automatic tool compensation (T
series) or tool length automatic compensation (M series).
NOTE
Set a radius value irrespective of whether the diameter
programming or the radius programming is specified.