4. DESCRIPTION OF PARAMETERS
B–63610EN/01
296
6756
Integrated value of general–purpose integrating meter drive signal (TMRON)
ON time II
Setting entry is acceptable.
[Data type] 2–word
[Unit of data] One min
[Valid data range] 0 to 99999999
This parameter displays the integrated value of a time while input signal
TMRON from PMC is on.
The actual integrated time is the sum of this parameter No. 6755 and
parameter No. 6756.
6757 Operation time (integrated value of one automatic operation time) I
Setting entry is acceptable.
[Data type] 2–word
[Unit of data] One ms
[Valid data range] 0 to 60000
6758 Operation time (integrated value of one automatic operation time) II
Setting entry is acceptable.
[Data type] 2–word
[Unit of data] One min
[Valid data range] 0 to 99999999
This parameter displays the one automatic operation drive time (neither
stop nor hold state included). The actual time accumulated during
operating is the sum of this parameter No. 6757 and parameter No. 6758.
The operation time is automatically preset to 0 during the power–on
sequence and the cycle start from the reset state.