B–63610EN/01
4. DESCRIPTION OF PARAMETERS
11
#7
RMVx0012
#6 #5 #4
AIC
#3 #2 #1 #0
MIRx
RMVx MIRx
Setting entry is acceptable.
[Data type] Bit axis
MIRx Mirror image for each axis
0 : Mirror image is off.
1 : Mirror image is on.
AIC The travel distance of an axis command is:
0: Determined by the value specified with the address.
1: Always handled as an incremental value.
RMVx Releasing the assignment of the control axis for each axis
0 : Not released
1 : Released
NOTE
RMVx is valid when RMBx in parameter 1005#7 is 1.
0020
I/O CHANNEL: Selection of an input/output device or selection of input device in
the foreground
Setting entry is acceptable.
[Data type] Byte
[Valid data range] 0 to 35
I/O CHANNEL: Selection of the input/output device to be used
The CNC provides the following interfaces for data transfer to and from
the host computer and external input/output devices:
D Input/output device interface (RS–232C serial port 1, 2)
D Remote buffer interface (RS–232C/RS–422)
D Memory card interface
D DNC1/DNC2 interface
Data can be transferred to and from a personal computer connected via the
FOCAS1/Ethernet or FOCAS1/HSSB.
In addition, data can be transferred to and from the Power Mate via the
FANUC I/O Link.
This parameter selects the interface used to transfer data to and from an
input/output device.