B–63610EN/01
4. DESCRIPTION OF PARAMETERS
221
5115
Clearance of canned cycle G83
[Data type] Word
[Unit of data]
Increment system IS-A IS-B IS-C Unit
Millimeter input 0.01 0.001 0.001 mm
Inch input 0.001 0.0001 0.0001 inch
[Valid data range] 0 to 32767
This parameter sets the clearance of peck drilling cycle G83.
G83 for 16–MC
q : Depth of cut
d : Clearance value
R point
Z point
q
q
q
d
d
Fig.4.24.1 (c) Peck drilling cycle G83
5121
Override value for retraction in boring cycle (G85, G89)
[Data type] Byte
[Unit of data] 100%
[Valid data range] 0, 1 to 20
Set the override value of retraction in a boring cycle.
If 20 or a greater value is specified in this parameter, the override is set to
2000%. If 0 is specified, this parameter becomes invalid, and the
retraction speed becomes two times the cutting speed.