4. DESCRIPTION OF PARAMETERS
B–63610EN/01
146
#7
M3B
3404
#6
EOR
EOR
#5
M02
M02
#4
M30
M30
#3 #2
SBP
SBP
#1
POL
POL
#0
NOPM3B
[Data type] Bit
NOP When a program is executed, a block consisting of an O number, EOB, or
N number is:
0 : Not ignored, but regarded as being one block.
1 : Ignored.
POL For a command address allowing a decimal point, omission of the decimal
point is:
0 : Enabled
1 : Disabled (P/S alarm No.5073)
SBP Address P of the block including M198 in the subprogram call function
0 : Indicating a file number
1 : Indicating a program number
M30 When M30 is specified in a memory operation:
0 : M30 is sent to the machine, and the head of the program is
automatically searched for. So, when the ready signal FIN is returned
and a reset or reset and rewind operation is not performed, the
program is executed, starting from the beginning.
1 : M30 is sent to the machine, but the head of the program is not searched
for. (The head of the program is searched for by the reset and rewind
signal.)
M02 When M02 is specified in memory operation
0 : M02 is sent to the machine, and the head of the program is automati-
cally searched for. So, when the end signal FIN is returned and a reset
or reset and rewind operation is not performed, the program is
executed, starting from the beginning.
1 : M02 is sent to the machine, but the head of the program is not searched
for. (The head of the program is searched for by the reset and rewind
signal.)
EOR When the end–of–record mark (%) is read during program execution:
0 : P/S alarm No.5010 occurs. (Automatic operation is stopped, and the
system enters the alarm state.)
1 : No alarm occurs. (Automatic operation is stopped, and the system is
reset.)
M3B The number of M codes that can be specified in one block
0 : One
1 : Up to three