4. DESCRIPTION OF PARAMETERS
B–63610EN/01
358
3. Built–in macro program number (parameters No. 12011 and No.
12012)
4. Built–in macro series and edition (parameters No. 12015 and No.
12016)
5. Built–in macro G code and relative program number (parameters
No. 12020 to No. 12049)
NOTE
1 If the password is not zero, the password cannot be changed
for the built–in macro data.
2 If all of the following conditions are satisfied, the keyword
cannot be changed.
1)A password is specified. (Password is not zero.)
2)The macro program number range of the built–in data of
FROM is different from the built–in macro program
number range specified in the parameter.
3)A program is entered.
12015 Series for built–in macro
12016 Edition for built–in macro
[Data type] Word
[Valid data range] 0 to 9999
These parameters specify the series and edition of the FROM file for
built–in macro. The series and edition are placed in the FROM file when
the built–in macro data is saved and can be checked on the system
configuration screen.
NOTE
1 This parameter is rewritten by the built–in macro data in
FROM at power–up or at a reload operation.
2 If the key of parameter No. 12013 is locked, the built–in
macro data in FROM is used.
3 If this parameter is set to 0, the series or edition of the FROM
file for built–in macro is not displayed on the system
configuration screen.
12020 G code number for built–in macro (first set)
12023 G code number for built–in macro (second set)
12047 G code number for built–in macro (tenth set)
[Data type] Word
[Valid data range] 1 to 999