
B–63610EN/01
4. DESCRIPTION OF PARAMETERS
241
5300 Tapping axis in–position width in rigid tapping
5301 Spindle in–position width in rigid tapping
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
These parameters are used to set tapping axis and spindle in–position
widths in rigid tapping.
NOTE
1 If an excessively large value is specified, the threading
precision will deteriorate.
2 When rigid tapping is performed using the second spindle
(T series)
• When the SPR parameter (bit 1 of parameter No.5204)
is set to 0, the settings of parameter No.5300 and
No.5301 are applied to the second spindle, as well as to
the first spindle.
• When the SPR parameter (bit 1 of parameter No.5204)
is set to 1, the settings of parameters No.5302 and
No.5303 are applied to the second spindle.
5302
Tapping axis in–position width in rigid tapping using the second spindle
5303
Spindle in–position width in rigid tapping using the second spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
These parameters are used to set spindle and tapping axis in–position
widths in rigid tapping using the second spindle.
NOTE
These parameters are enabled when the SPR parameter
(bit 1 of parameter No.5204) is set to 1.
5308 In–position width at point R in rigid tapping (tapping axis)
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
This parameter is used to set the tapping axis in–position width at point R
in rigid tapping.