4. DESCRIPTION OF PARAMETERS
B–63610EN/01
132
3151 Number of the axis for which the first load meter for the servo motor is used
3152 Number of the axis for which the second load meter for the servo motor is used
3153 Number of the axis for which the third load meter for the servo motor is used
3154 Number of the axis for which the fourth load meter for servo motor is used
[Data type] Byte
[Valid data range] 0, 1, . . . , the number of control axes
Set the numbers of the axes for which measurement values on the load
meters for the fourth servo motors are displayed. Set the parameters to 0
for those axes for which a load meter need not be displayed.
3163 Time required to smooth the spindle load meter readings
[Data type] Byte
[Unit of data] 32 ms
[Valid data range] 0 to 32
When the spindle load meter reading is displayed (see the description of
the SLM parameter (bit 6 of parameter No.3108)), smoothing can be
applied to the spindle load meter reading to prevent flickering. This
parameter sets the time width for smoothing.
Setting Time for smoothing (msec)
0 256
1 32
2 64
3 96
: :
: :
32 1024
Each smoothing operation is performed for a time width of between 32 ms
and 1024 ms.
#7
3190
#6 #5 #4 #3
HUN
#2 #1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
HUN Hungarian display is:
0 : Not performed.