4. DESCRIPTION OF PARAMETERS
B–63610EN/01
334
#7
8200
#6 #5 #4 #3
AZP
#2
AZR
#1 #0
AAC
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
AAC
0 : Does not perform angular axis control.
1 : Performs inclined axis control.
AZR
0 : The machine tool is moved along the Cartesian axis during manual
reference position return along the slanted axis under angular axis
control.
1 : The machine tool is not moved along the Cartesian axis during
manual reference position return along the slanted axis under angular
axis control.
AZP When an angular axis moves, the reference position return completion
signal for the Cartesian axis, ZPx <F094, F096, F098, F100, or F116>, is:
0 : Not cleared.
1 : Cleared.
#7
ADG
8201
#6 #5
ACL
#4 #3 #2
AO3
#1
AO2
#0
AOT
[Data type] Bit
AOT When angular axis control is enabled, the values indicating the area for
stored stroke check 1 (parameters Nos. 1320, 1321, 1326 and 1327) are
treated as:
0 : Coordinates in the angular coordinate system.
1 : Coordinates in the Cartesian coordinate system.
AO2 When angular axis control is enabled, the values indicating the area for
stored stroke check 2 (parameters Nos. 1322 and 1323) are treated as:
0 : Coordinates in the angular coordinate system.
1 : Coordinates in the Cartesian coordinate system.
AO3 When angular axis control is enabled, the values indicating the area for
stored stroke check 3 (parameters Nos. 1324 and 1325) are treated as:
0 : Coordinates in the angular coordinate system.
1 : Coordinates in the Cartesian coordinate system.
4.51
PARAMETERS OF
ANGULAR AXIS
CONTROL