B–63610EN/01
4. DESCRIPTION OF PARAMETERS
83
1731
Arc radius value corresponding to a maximum feedrate
[Data type] 2–word
[Unit of data]
Unit IS–A IS–B IS–C Unit
Linear axis
(millimeter machine)
0.01 0.001 0.0001 mm
Linear axis
(inch machine)
0.001 0.0001 0.00001 inch
[Valid data range] 1000 to 99999999
Set the arc radius corresponding to the maximum feedrate set in parameter
No.1730. Set this parameter when the arc radius–based feedrate clamping
function is enabled.
1732
Minimum value (RV min) for arc radius–based feedrate clamp
[Data type] Word
Valid data range
y
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 0 to 15000 0 to 12000
Inch machine 0.1 inch/min 0 to 6000 0 to 4800
The arc radius–based feedrate clamping function reduces the maximum
feedrate as the arc radius decreases. When the specified maximum
feedrate is not greater than RV min (minimum value for arc radius–based
feedrate clamping), RV min is used as the maximum feedrate.
1762
Exponential acceleration/deceleration time constant for cutting feed in the look–
ahead control mode
[Data type] Word axis
[Unit of data] 1 ms
[Valid data range] 0 to 4000
Set an exponential acceleration/deceleration time constant for cutting
feed in the look–ahead control mode.
1763
Minimum speed in exponential acceleration/deceleration for cutting feed in the
look–ahead control mode
[Data type] Word axis
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotation axis 1 deg/min 6 to 15000 6 to 12000
Set minimum speed (FL) in exponential acceleration/deceleration for
cutting feed in the look–ahead control mode.