4. DESCRIPTION OF PARAMETERS
B–63610EN/01
62
JRV Manual continuous feed (jog feed)
0: Jog feed is performed at feed per minute.
1: Jog feed is performed at feed per rotation.
NOTE
Specify a feedrate in parameter No.1423.
#7
RTV
1403
#6 #5 #4 #3 #2 #1 #0
MIF
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
MIF Cutting feedrates at feed per minute is specified by F commands
0: In units of 1 mm/min for millimeter machines or 0.01 inches/min for
inch machines.
1: In unit of 0.001 mm/min for millimeter machines or 0.00001
inches/min for inch machines.
NOTE
M series are not equipped with this parameter. Cutting
feedrates are specified by F commands in units of 0.001
mm/min for millimeter machines or 0.00001 inches/min for
inch machines.
RTV Override while the tool is retracting in threading
0 : Override is effective.
1 : Override is not effective.
#7
1404
FC0
#6 #5
EDR
EDR
#4 #3
FRV
FRV
#2
F8A
F8A
#1
DLF
DLF
#0
HFC
[Data type] Bit
HFC The feedrate for helical interpolation is:
0: Clamped so that the feedrates along an arc and linear axis do not
exceed the maximum cutting feedrate specified by parameter
(No.1422 or 1430).
1: Clamped so that the composite feedrate along an arc and linear axis does
not exceed the maximum cutting feedrate specified by parameter
(No.1422).
DLF After a reference potition is set, manual reference position return
performed at:
0 : Rapid traverse rate (parameter No.1420)
1 : Manual rapid traverse rate (parameter No.1424)