B–63610EN/01
4. DESCRIPTION OF PARAMETERS
349
#7
8650
#6 #5
PGU
#4
CKM
#3
DMA
#2
EKY
#1
CNA
#0
RSK
[Data type] Bit
RSK When the RESET key is pressed, the key code is:
0 : Not passed to the application in the C executor.
1 : Passed to the application in the C executor.
CNA When an NC alarm is issued during the display of the user screen for the C
executor:
0 : The NC alarm screen can be displayed depending on the setting of bit
7 (NPA) of parameter No.3111.
1 : The NC alarm screen is not displayed.
EKY When the C language executor is used, the extended portion of the MDI
keys (9 to 11 lines) is:
0 : Not read.
1 : Read.
DMA When the C language executor is used, transfer via RS–232–C is:
0 : Not made as DMA transfer.
1 : Made as DMA transfer.
CKM When the C language executor is used, the bit matrix of the MDI keys is:
0 : Not transferred to the NC.
1 : Transferred to the NC.
Set this bit to 1 only when the NC needs to directly read the bit matrix.
Usually, set this bit to 0.
PGU When the user screen for the C executor is assigned as an NC program
screen:
0 : The common screen number is used.
1 : The screen number for each operation mode is used.
NOTE
Bits 0 to 5 of this parameter is used with the C executor. Any
modifications to the value set for bits 0 to 5 of this parameter
does not become effective until after the system is next
powered on.
#7
8651
#6 #5 #4 #3 #2 #1 #0
CFS
NOTE
When this parameter has been set, the power must be
turned off before operation is contimued.
[Data type] Bit
CFS FACTOLINK software in:
0 : Dedicated memory card is valid.
1 : FROM is valid.
4.55
OTHER
PARAMETERS