B–63610EN/01
4. DESCRIPTION OF PARAMETERS
117
#7
COR
#6 #5 #4 #3
FKY
#2
SKY
#1
CEM
#0
3100
[Data type] Bit
CEM On screens such as the operation history screen and help screen, keys on
the MDI panel are indicated:
0 : In English.
1 : With graphics qualifying for CE marking. (A character generator
supporting graphics qualifying for CE marking is required.)
SKY MDI key board use:
0 : Standard keys.
1 : Small keys.
NOTE
Set this parameter when using the 9.5”/10.4” LCD (with ten
soft keys). After this parameter has been set, the power must
be turned off then back on for the setting to become
effective.
FKY MDI keyboard
0 : Small type keys are used.
1 : Standard keys are used.
NOTE
Set this parameter when using the 7.2”/8.4” LCD (with seven
soft keys). After this parameter has been set, the power must
be turned off then back on for the setting to become
effective.
COR Display
0 : Monochrome display
1 : Color display
NOTE
When using the 8.4” LCD, set this bit to 1.
#7
3101
#6 #5 #4
BGD
#3 #2 #1
KBF
#0
[Data type] Bit
KBF When the screen or mode is changed, the contents of the key–in buffer are:
0 : Cleared.
1 : Not cleared.
4.19
PARAMETERS OF
MDI, DISPLAY,
AND EDIT