B–65162E/03
9.CONNECTION
201
NOTE
1 Four–conductor polyvinyl heavy–duty power cable (JIS C3312)
2 Fire–retardant polyflex wire (maximum conductor temperature 105°C) or equivalent to LMFC
manufactured by The Furukawa Electric Co., Ltd.
3 Applicable crimp terminals: 5.5–4S for the PSMR–3 and –5.5
8–4S for the PSM–11
38–6S for the PSM–37
– Connection with the PSM–HV
R
S
T
G
L1
L2
L3
Main power
supply
AC400V
AC460V
50/60Hz
Circuit
breaker 1
MCC
AC
reactor
TB2
(L1)
(L2)
(L3)
PSM–HV
Table.9.2.1 (b) Cable K1 Specifications
Applicable cable
Heat–resistant cable (Note 1)
PSM–18HV R, S, and T phase lines and grounding line 8mm
2
or larger M6
PSM–30HV R, S, and T phase lines and grounding line 14mm
2
or larger M6
PSM–45HV R, S, and T phase lines and grounding line 22mm
2
or larger M6
R, S, and T phase lines 38mm
2
or larger M10
–
Ground line 22mm
2
or larger M6
NOTE
1 Four–conductor polyvinyl heavy–duty power cable (JIS C3312)
2 Fire–retardant polyflex wire (maximum conductor temperature 105°C) or equivalent to LMFC
manufactured by The Furukawa Electric Co., Ltd.