B–65162E/03
11. OPTION RELATED TO SPINDLE
495
Parameter No.
Description
FS0 Description
FS16
FS15–TT
FS0–TT
1st
Description
FS16
2nd1st
FS0–TT
2nd
Setting of acceleration/deceleration time constants (Continued)
6300 6480 6300 3480 3700 4336
Flux switching point for calculating the accelera-
tion/deceleration time constant for spindle syn-
chronization control
(The same value must be set for both spindles.)
6304 6484 6304 3484 3704 4340
Bell–shaped acceleration/deceleration time
constant for spindle synchronization control
(The same value must be set for the 1st and 2nd
spindles.)
Setting of a velocity loop gain and motor voltage
6544
6545
6684
6685
6544
6545
3044
3045
3184
3185
4044
4045
Velocity loop proportional gain for spindle synchro-
nization control
(selected by DI signal CTH1A from the PMC)
6552
6553
6692
6693
6552
6553
3052
3053
3192
3193
4052
4053
Velocity loop integral gain for spindle synchroniza-
tion control
(selected by DI signal CTH1A from the PMC)
6585 6725 6585 3085 3225 4085 Motor voltage for spindle synchronization control
6310 6490 6310 3490 3710 4346 Incomplete integral coefficient