B–65162E/03
9.CONNECTION
259
Cables should be connected to the SPM and spindle motor using crimp
terminals that match the motor, as listed in the following table.
Cable K10 (power line) specification
Motor model Applicable cable Terminal screw
αseries αP series
α (HV)
series
αC series
Heavy–duty pow-
er cable (Note 1)
Heat–resistant
cable (Note 2)
Amplifi-
er side
Motor
side
α0.5
–––
––– ––– 0.75mm
2
or larger ––– M4 (Note 3)
α1 ––– ––– αC1 2mm
2
or larger ––– M4 M5
α1.5, α2 ––– ––– αC1.5, αC2 3.5mm
2
or larger 3.5mm
2
or larger M4 M5
α3 ––– ––– αC3 5.5mm
2
or larger 3.5mm
2
or larger M4 M5
α6 αP8, αP12 ––– αC6 ––– 3.5mm
2
or larger M4 M5
α8 αP15 ––– αC8 ––– 5.5mm
2
or larger M4 M5
α12 αP18 ––– αC12 14mm
2
or larger 8mm
2
or larger M6 M5
α15 αP22 ––– αC15 ––– 14mm
2
or larger M6 M5
α18 αP30 ––– αC18 ––– 14mm
2
or larger M6 M8
α22
αP40, αP50,
αP60
––– αC22 ––– 22mm
2
or larger M6 M8
α30 ––– ––– ––– ––– 38mm
2
or larger M10 M10
α40 ––– ––– ––– ––– 50mm
2
or larger M10 M10
––– –––
α6HV, α8HV,
α12HV
––– ––– 3.5mm
2
or larger M6 M5
––– –––
α15HV,
α18HV
––– ––– 5.5mm
2
or larger M6 M5
––– ––– α22HV ––– ––– 8mm
2
or larger M6 M5
––– ––– α30HV ––– ––– 14mm
2
or larger M6 M10
––– ––– α40HV ––– ––– 22mm
2
or larger M6 M10
––– ––– α60HV ––– ––– 50mm
2
or larger M10 M10
NOTE
1 Four–conductor polyvinyl heavy–duty power cable (JIS C3312)
2 Fire–retardant polyflex wire (maximum conductor temperature 105°C) or equivalent to LMFC
manufactured by The Furukawa Electric Co., Ltd.
3 Use the following AMP connector kit: A63L–0001–0428/CT