B–65162E/03
11. OPTION RELATED TO SPINDLE
497
FS16 : No. 4014 #3=1
FS15 : No. 3014 #3=1
FS0 : No. 6514 #3=1
D As the speed detecting signal (SDTA) is used for switching speed
detection, it cannot be used for gear change speed detection, etc.
D As the error detection function for switching operation, the alarm
(AL–15) is issued if the magnetic contactor signal (RCHA,
RCHHGA) is not applied within 1 second of the power line switch
signal (RCHPA) being output.
The connections of Type A and Type B, below, depend on the
specification of a spindle motor with the output switch function. When
low–speed output characteristics mode is selected, MCC1 is on, and
MCC2 is off. When high–speed output characteristics mode is selected,
MCC1 is off, and MCC2 is on.
(1) Type A
AC
spindle
motor
CNC
and
PMC
JY2
JA7B
Spindle amplifier
module (SPM)
TB2
U
V
W
Electromagnetic
contactor switching
circuit
Single phase
200VAC
Relay circuit
Communica-
tion cable
G
G
Auxilially
contact
Electromagnetic contactor
for switching power cable
MCC 2
U
V
W
G
U
V
W
MCC1
X
Y
Z
U
V
W
X
Y
Z
Auxilially
contact
NOTE
The power supply module is omitted from the figure.
Items such as units and cables other than the spindle
amplifier module and, AC spindle motor, which are
surrounded by the unbroken line, must be provided by the
machine tool builder.
11.5.4
Connections