B–65162E/03
11. OPTION RELATED TO SPINDLE
427
NOTE
1 This function can also be used for spindle orientation of
external stop position setting type and incremental
command type.
2 This function cannot be used for orientation during spindle
synchronization.
(2) System configuration
The high–speed orientation function can be used with the following
system configurations:
1) System in which a position coder connected to a spindle on a
one–to–one basis is installed
2) Motor system built into a spindle
3) System in which a motor with a built–in MZ sensor is connected
to a spindle on a one–to–one basis
NOTE
This function cannot be used with an orientation system of
external one–rotation signal type that uses a proximity
switch.
(3) Signal
See Section 11.1.1.5.
(4) Description of operation
1) When orientation operation is started from a speed higher than the
upper orientation speed limit
ORCMA (orientation command)
ORARA (orientation completion signal)
Motor speed
Upper orientation speed limit