B–65162E/03
10. INTERFACE SIGNALS
365
(2) 2nd Spindle Signal Address
FS0
FS0–TT
HEAD2
FS15
(Note 1)
FS16
Path 1 Path 2
#7 #6 #5 #4 #3 #2 #1 #0
F285 F1485 F245 F049 F1049 ORARB
TLMB LDT2B LDT1B SARB SDTB SSTB ALMB
F286 F1486 F244 F050 F1050 MOAR2B MOAR1B POAR2B SLVSB RCFNB RCHPB CFINB CHPB
F287 F1487 F247 F051 F1051 EXOFB SORENB MSOVRB INCSTB PC1DTB
F248 SLDMB15 SLDMB14 SLDMB13 SLDMB12 SLDMB11 SLDMB10 SLDMB9 SLDMB8
F249 SLDMB7 SLDMB6 SLDMB5 SLDMB4 SLDMB3 SLDMB2 SLDMB1 SLDMB0
F250 SSPDB15 SSPDB14 SSPDB13 SSPDB12 SSPDB11 SSPDB10 SSPDB9 SSPDB8
F251 SSPDB7 SSPDB6 SSPDB5 SSPDB4 SSPDB3 SSPDB2 SSPDB1 SSPDB0
F252 SSPAB7 SSPAB6 SSPAB5 SSPAB4 SSPAB3 SSPAB2 AAPAB1 SSPAB0
(3) Spindle control DO signals
Symbol Signal Description
ALMA, B Alarm signal
Output when a spindle alarm occurs.
0 : Normal state
1 : Alarm state
SSTA, B
Speed zero
detection signal
Output when the actual spindle motor speed does not ex-
ceed the speed zero detection level.
1 : Zero speed
SDTA, B
Speed detection
signal
Output when the actual spindle motor speed does not ex-
ceed the preset speed.
1 : Less than preset speed
SARA, B
Speed match
signal
Output to the velocity command when the actual spindle mo-
tor speed reaches the preset range.
1 : Speed match
LDT1A, B
Load detection
signal 1
Output when the detected load is greater than the specified
load detection level.
LDT1 and LDT2 can be set to a different level.
1 : Greater than the specified load
LDT2A, B
Load detection
signal 2
Output when the detected load is greater than the specified
load detection level.
1 : Greater than the specified load
TLMA, B
Torque limiting
signal
1 : The limit is applied to the torque.
ORARA, B
Orientation
complete signal
Output when the spindle stops near the specified position af-
ter the orientation command is entered.
1 : Orientation is completed.
CHPA, B
Power line
change signal
Used for spindle switching control.
0 : Main spindle
1 : Sub spindle
CFINA, B
Spindle switch-
ing completion
signal
Used for spindle switching control.
0 : Main spindle
1 : Sub spindle
RCHPA, B
Power line
change signal
Used for speed range switching control.
0 : High-speed range
1 : Low-speed range
RCFNA, B
Speed range
switching
completion
signal
Used for speed range switching control.
0 : High-speed range
1 : Low-speed range