2. CONFIGURATION AND ORDERING INFORMATION
B–65162E/03
34
– Connecting a power transformer
Power transformers must be set according to the supply voltage used.
(a) Connection points of power transformers (A80L–0024–0006 and A80L–0026–0003) for PSMR–3
Supply voltage Connection points at the primary Other connection points
AC380V R – 6, S – 14, T – 22
AC400V R – 4, S – 12, T – 20
AC415V R – 4, S – 12, T – 20
Make 8–16 and 16–24 connections by using supplied
AC440V R – 3, S – 11, T – 19
cables.
AC460V R – 3, S – 11, T – 19
AC480V R – 2, S – 10, T – 18
Transformer (A80L–0024–0006 and A80L–0026–0003) accessories
Part name Drawing number Quantity
Cable A660–8001–T532 2
Cable A660–8004–T926 2
Bolt A30L–0001–0021 4
(b) Connection points of power transformers for PSMR–5.5, PSM–5.5, PSM–11, PSM–15, PSM–26,
PSM–30, PSM–37, and PSM–45
Supply voltage Connection points at the primary Remarks
AC380V R – R1, S – S1, T – T1 (380–V tap)
AC400V R – R1, S – S1, T – T1 (380–V tap)
AC415V R – R2, S – S2, T – T2 (415–V tap)
AC440V R – R2, S – S2, T – T2 (415–V tap)
AC460V R – R3, S – S3, T – T3 (460–V tap)
AC480V R – R3, S – S3, T – T3 (460–V tap)