B–65162E/03
11. OPTION RELATED TO SPINDLE
459
D When an emergency stop occurs during orientation, the orientation
command signal must be reset (”0”).
Return the ATC arm to the safe position so that it will not be damaged
if the spindle or tool rotates when the power is turned on.
(c) Clutch/gear signals (CTH1A, CTH2A)
D When there are two or more speed change gear stages between the
spindle and spindle motor, these signals are used to select a spindle
control parameter (position gain, gear ratio, velocity loop gain).
D Depending on the clutch or gear state, make settings according to the
table below. Names such as HIGH GEAR are assigned only for
convenience. Arbitrary names may be assigned to the actual gears.
CTH1A CTH2A
0 0 : HIGH GEAR
0 1 : MEDIUM HIGH GEAR
1 0 : MEDIUM LOW GEAR
1 1 : LOW GEAR
(2) DO Signals (CNC to PMC)
(a) Spindle control signals
#7 #6 #5 #4 #3 #2 #1 #0
FS0 FS15 FS16
ORARA TLMA LDT2A LDT1A SARA SDTA SSTA ALMA
: F281 F229 F405
First spindle control output signal
#7 #6 #5 #4 #3 #2 #1 #0
FS0 FS15 FS16
ORARB TLMB LDT2B LDT1B SARB SDTB SSTB ALMB
: F285 F245 F049
Second spindle control output signals
(b) Orientation (fixed position stop) completion signal (ORARA)
D When the orientation command is input and the spindle has stopped
near the preset fixed position (for example, within "1°), it becomes
”1”.
Condition for ORARA to become ”1”
Near to fixed position is set to the parameter.
If the above 3 conditions are satisfied, the orientation complete signal
is output.
If the orientation completion signal is not issued within a set period of
time after the orientation command signal is input, it is considered to
be abnormal. So it should be detected by the power magnetic sequence
and an orientation alarm should be issued.
Set the condition for judging that the spindle is near the fixed position
in the parameter used to specify the detection level for orientation
completion.
D Tool change or workpiece loading /unloading operations can be started
when this signal is ”1”.