9. CONNECTION
B–65162E/03
216
– Combination of the PSMR and the SPM–11 (with a fan adapter)
200S
200R
PSM–11
CX1B
(3)
(2)
(1)
350/X
CX1A
(3)
(2)
(1)
PSMR
350/X
Cable specification: Two–conductor polyvinyl heavy–duty power cable
(JIS C3312), conductor size of 1.25 mm
2
(50/0.18),
PVC sheath 9.6 mm in diameter
Connector specification: AMP connector with receptacle housing 1–178128–3 and
receptacle contact 1–175218–2
NOTE
If the PSMR is combined with the SPM–11 (with a fan adapter), the position at which to connect
cable K4 differs from the connection for other combinations. See the connection diagram under
”Power supply module (PSMR); connected with the SPM–11 (with a fan adapter)” in Section
9.2.1 for details.
(5) Detailed description of the connection of cable K5
Cable K5 is used to connect 24 VDC control power to each module.
ESP
0V
+24V
PSM
CX2B
(3)
(2)
(1)
CX2A
(3)
(2)
(1)
SVM
SPM
250/X250/X
Cable specification: Three–conductor polyvinyl heavy–duty power cable (JIS C3312),
conductor size of 1.25 mm
2
(50/0.18),
PVC sheath 10.5 mm in diameter
Connector specification: AMP connector with receptacle housing 1–178288–3 and
receptacle contact 1–175218–2
SPMC