B–65162E/03
9.CONNECTION
269
(12) Detailed description of connection of cable K33
(a) Use for load meter or speedometer
Required connector (HONDA)
Connector PCR–E20FS
Housing PCR–V20LA
(solder type)
Recommended cable (wire only): A66L–0001–0284#10P
See Appendix C for details.
10 20
9
19
818
7
17
616
515
414
3
13
2
12
111
Pin assignment of connector JY1
SPM
JY1
(1)
(2)
(20)
(16)
(18)
(17)
(19)
OVR1
OVR2
0V
LM
0M
SM
0M
VR
R1
Power magnetics cabinet
Can be overridden in 1 %
steps, using the variable
resistor (Note 1).
Load meter
Speedometer
Connector PCR–E20FA
Housing PCR–V20LA
Cable specification: 0.09mm
2
common shielded cable
OVR1
OVR2
0M
SM
0V
0M
LM
Required connector (HONDA)
Connect the shielded wire to a 0 V potential (pin 20).
*(Note 2)
*
*
*
*
*
*
NOTE
1 Select such an external resistance such that VR + R1 falls within the range between 2 kΩ and
10 kΩ .
2 Pins indicated * are intended to input or output signals used on a spindle check board. Do not
connect any other signal line to them.