B–65162E/03
10. INTERFACE SIGNALS
397
Symbol DescriptionSignal
CSS
Constant sur-
face speed
control signal
1 : Under constant surface speed control
FSPSY
MSPSYC
Spindle syn-
chronization
control signal
(Under devel-
opment)
1 : Under spindle synchronization control
FSPPH
MSPPHS
Spindle phase
synchroniza-
tion control sig-
nal (Under de-
velopment)
1 : Under spindle phase synchronization control
SYCAL
SPSYAL
Spindle syn-
chronization
control alarm
signal (Under
development)
1 : Spindle synchronization control alarm
S31 - S00
Spindle func-
tion code signal
Sxxx
AR15 - AR00
Actual spindle
speed signal
SLDM15 -
SLDM00
Load meter
data
0 to 32767 (+10 V)
SSPD15 -
SSPD00
Motor frequen-
cy data
0 to 16383 (maximum motor speed)
SSPA07 -
SPMA00
Spindle alarm
data
Alarm number
RTAP
Rigid tapping–
in–progress
signal
1 : Rigid tapping in progress
D Spindle motor and spindle amplifier module enter the operable state
by
*
ESPA = 1. When *ESPA is set to 0, the spindle amplifier module
outputs the MCOFF signal and the spindle motor does not operate.
D If
*
ESPA = 0 is set during the motor rotation, the spindle motor
smoothly decelerates to a stop. Then, it outputs the MCOFF signal.
D If
*
ESPA = 1 then occurs again, the spindle motor enters the rotateable
state, and so will begin to rotate as soon as a rotation command is
issued. For this reason, the command signal (speed command, normal
operation command, or reverse operation command) to the spindle
amplifier module should be reset at the same time an emergency stop
signal is input.
10.4.3
Emergency Stop Signal
(*ESPA)