B–65162E/03
11. OPTION RELATED TO SPINDLE
501
D Spindle indexing mode
D The spindle orientation is completed.
(c) Electromagnetic contactor for the speed range switching status signal (RCHA)
[Function] The opening and closing status signal of the electromagnetic contactor for
a low-speed range of the spindle motor is input.
0 : The low-speed range side electromagnetic contactor is open.
1 : The low-speed range side electromagnetic contactor is closed.
[Usage] The status of the auxiliary contact (”A” contact) of electromagnetic
contactor for a low-speed is usually input.
The status of the low-speed range side electromagnetic contactor is input
as this signal for parameter NO. 4014 #3=1 (FS16).
[Function] The selection status signal of the electromagnetic contactor for the spped
range switching of the spindle motor is inputted.
0 : The high-speed range is selected.
1 : The low-speed range is selected.
[Usage] When the electromagnetic contactor changes from the low-speed side to
the high-speed side, this signal is set from ”1” to ”0” after it is confirmed
that the electromagnetic contactor on the low-speed side is off and that the
electromagnetic contactor on the high-speed side is on.
When the electromagnetic contactor changes from the high-speed side to
the low-speed side, this signal is set from ”0” to”1” after it is confirmed
that the electromagnetic contactor on the high-speed side is off and that
the electromagnetic contactor on the low-speed side is on.
(d) High-speed range side electromagnetic contactor status signal (RCHHGA)
[Function] The opening and closing status signal of the electromagnetic contactor for
a high-speed range of the spindle motor is input.
0 : The high-speed range side electromagnetic contactor is open.
1 : The high-speed range side electromagnetic contactor is closed.
[Usage] The status of the auxiliary contact (”A” contact) of the electromagnetic
contactor for a high-speed range is usually input.
This signal is effective for parameter NO. 4014 #3=1 (FS16).