B–65162E/03
3. HOW TO SELECT THE POWER SUPPLY MODULE
57
(1) When two α22/2000 servo motors and one αP50 spindle motor are
used
Servo motor α22/2000
Continuous rated output : 3.8 kW
Maximum output at acceleration : 7.5 kW
Spindle motor αP50
Continuous rated output : 22 kW
Maximum output at acceleration : 36 kW
Rated output capacity of power supply module y Σ spindle motor
continuous rated output 1.15 + Σ servo motor continuous rated
output 0.6
= 22 1.15 + 3.8 2 0.6
= 29.86 Condition 1
Maximum output capacity of the power supply module y Σ
maximum output of the spindle motor at acceleration + Σ maximum
output of the servo motors at acceleration (simultaneous
acceleration/deceleration)
= 36 + 7.5 2
= 51.0 Condition 2
According to conditions 1 and 2, PSM–30 is selected as the power
supply module.
(2) When two α6/3000 servo motors and one α22/2000 servo motor, and
one α3 spindle motor are used
Servo motor α6/3000
Continuous rated output : 1.4 kW
Maximum output at acceleration : 6.2 kW
Servo motor α22/2000
Continuous rated output : 3.8 kW
Maximum output at acceleration : 7.5 kW
Spindle motor α3
Continuous rated output : 3.7 kW
Maximum output at acceleration : 6.6 kW
Rated output capacity of power supply module y Σ spindle motor
continuous rated output 1.15 + Σ servo motor continuous rated
output 0.6
= 3.7 1.15 + (1.4 2 + 3.8) 0.6
= 8.215 Condition 3
Since the rated output capacity of the power supply module is not
higher than 11kW, the maximum output capacity can be obtained
from the following expression:
3.3.5
Example of Selecting a
Power Supply Module
(PSM)