11. OPTION RELATED TO SPINDLE
B–65162E/03
516
(c) Switching completion signal (CFINA)
[Function] This signal shows by which spindle characteristic the spindle motor is
controlled.
0 : It is controlled by a main spindle characteristic.
1 : It is controlled by a sub spindle characteristic.
[Usage] The switching request signal (SPSLA) changes, and after it is confirmed
that this signal is corresponding to the switching request signal (SPSLA),
it moves to the next movement.
Since it is necessary that the motor power is off until this signal is
corresponding to the switching request signal (SPSLA) after the change
of the switching request signal (SPSLA), please set off the spindle
rotation command (SFRA/SRVA) and the spindle orientation command
(ORCM) at the switching operation.
(d) Speed zero signal (SSTA)
[Function] It becomes ”1” while the motor speed is below the speed zero detection
level which is set by parameter.
0 : It is above the speed zero detection level.
1 : It is below the speed zero detection level.
[Usage] At switching the spindle, it is necessary both that the motor power is off
and that the motor is stopping.
This signal is used for confirming whether the motor is stopping.